Radar level measurement wholesale manufacturer 2024

Excellent Radar level transmitter manufacturer: The second case is that, in order to ensure the fluidity of crude oil, offshore oil platforms usually use hot medium oil heating pipes to heat the crude oil to ensure that it is stored within a certain temperature range. As the crude oil in the lower tank contains a small amount of water, some of the bottom water will precipitate out of the bilge water after standing, and the water vapor will evaporate during the continuous heating process. The water vapor condenses on the antenna at the top of the tank to form water droplets, causing a strong false signal at the top. Therefore, false signals are suppressed within 0~0.25m and the suppression line is set to 120dB to avoid false signals caused by water vapor condensation and level jumps at the top. In response to this situation, after on-site analysis and research tests decided to do a good job of pre-dewatering treatment, the water content of the crude oil in the lower tank is controlled at less than 0.5%, the heating temperature of the crude oil tank is controlled so that the crude oil in the tank is lower than 65 ℃, and the instrumentation is covered with thermal insulation materials on the outside, etc. Through the above measures, the phenomenon of level jumping caused by the formation of condensation at the antenna of the radar liquid level meter is eliminated. Read extra info at radar level transmitter manufacturer.

There is AC interference and the voltage is high. For example, for the radar level meter used in the production line, the power supply requirement is 24VDC (typical value), but in the on-site measurement, it is found that the power supply is displayed as 27.2V, which is significantly higher than 24VDC, resulting in a large measurement result and even a radar level meter. crash phenomenon. The installation position of the radar level meter is incorrect, which leads to deviations in the measurement. For example, the accumulation of aggregates in the transfer bin is a “mountain”-shaped cone, but only one radar level meter is installed near the discharge port of the return belt. , the installation position is too close to the discharge opening of the return belt, and at the same time, it is too far from the discharge opening of the feeding belt on both sides. Just below the radar level meter is the drop point of the return belt. If the distance is too close, the aggregate in the falling process will interfere with the radar level meter and form false reflections.

Measuring principle of radar water level meter: The radar level gauge adopts the working mode of transmitting-reflecting-receiving. The electromagnetic wave emitted by the antenna is reflected by the surface of the measured object and then received by the antenna. After measuring the distance from the water surface to the radar antenna, the elevation of the water surface can be calculated according to the elevation of the radar antenna. The radar water level meter adopts pulse wave technology with low power consumption. It can be powered by two-wire 24 VDC, 485 interface output, or can be directly powered by 12 VDC, SDI-12 interface output, with high accuracy and wider application range.

Level Measurement Considerations: Taking advantage of a specific technology’s ability to reliably address the level measurement in either of these vessels, especially the blowdown flash tank, in a plug-and-play type installation and commissioning format is an easy way to ensure optimal performance. This forgoes calibration, external hardware or inputs. Estimates of up to 49 percent of the energy can be recovered through the use of flash steam routed to heat exchangers or the deaerator to preheat boiler makeup water or support the deaeration process, respectively. In addition, better level control technology at the boiler side eliminates energy losses resulting from unnecessary blowdown to prevent carryover conditions.

Secondly, in cement production, material level measurement encountered another difficulty is strong dust interference, especially pneumatic conveying powder silo, dust flying when feeding, low visibility, laser level meter and high energy ultrasonic level meter can not be measured, although radar level meter at this time can receive part of the surface echo. But the echo signal was also weakened. In addition, due to the uneven surface of the radar echo is refracted, will also lead to the existence of radar echo; In addition, there are some conditions from the bottom to the bin inflation, so that the material surface loose, material level measurement is more difficult.

KAIDI level transmitter manufacturer is dedicated in providing complete customized solutions for a wide range of industrial automation process applications – in material level, liquid flow, pressure and temperature. We are constantly developing and innovating, our core vision – “to provide solutions that exceed customers’ expectations. In 2012, the company successfully expanded its operations both locally and internationally, achieving global success and recognition for quality fork type level switch, magnetic level gauge products and services. Find more information on https://www.kaidi86.com/. The Magnetic Level Gauge all use vacuum tube technology, with a lifespan of 3-5 years, and protection grade is up to IP68, not easy to fade.

Humidity interference, when the humidity increases, it will cause the insulator resistance to decrease, the dielectric constant to increase, the skeleton to be fluffy, and the resistance to increase, resulting in an increase in leakage current and changes in capacitance and inductance. Also, it softens the colloid and reduces measurement accuracy. Chemical interference, chemical interference usually refers to some corrosive gases, such as acids and alkalis. The long-term action of these gases will not only damage the instrument and internal components, but also conduct electricity with the metal, affecting the normal operation of the radar level transmitter.

For the continuous measurement of corrosive, high viscosity, flammable and toxic liquids, liquid-liquid interface and solid-liquid interface that are difficult to measure by ordinary liquid level meter , ultrasonic level meter should be selected, but should not be used in occasions with large liquid level fluctuations . Ultrasonic level meter are suitable for measuring media that can fully reflect and transmit sound waves, but should not be used in vacuum. The ultrasonic flow meter should not be used in process equipment where internal obstacles affect the propagation of sound waves.

Effective Echo Management- Pulse radar technology generates echoes at certain time intervals. This feature enables radar sensors to handle echoes and distinguish echoes. A common occurrence in complex process vessels and solid material silos. This capability greatly enhances the accuracy of measurements in situations where traditional methods may struggle. The versatility and dependability of radar level measurement make it suitable for a range of applications. Here are some important areas where radar sensors excel- Process Tanks-In industries, radar level sensors are deployed to monitor levels in process tanks. Whether its chemicals, petroleum products or water treatment facilities radar sensors provide real time data to optimize process control. Storage Tanks- Large scale storage tanks require precise level monitoring to efficiently manage inventory and prevent overfilling or underfilling. Radar sensors are the trusted choice for maintaining inventory balance.

Power supply and output signal, the power supply has 220 V A C, 24 VDC, and the two-wire or four-wire system can be selected according to the needs. Output signal 4 ~ 20 mA DC or digital signal, select the appropriate model according to the needs. The above are all factors that need to be considered when selecting a radar level transmitter. The essence of the details is a serious attitude and a scientific spirit. I hope that every user can choose a suitable radar level meter.