Best rated flow meter wholesale manufacturer

Flow meter device wholesale manufacturer by Kaidi86: The second case is that, in order to ensure the fluidity of crude oil, offshore oil platforms usually use hot medium oil heating pipes to heat the crude oil to ensure that it is stored within a certain temperature range. As the crude oil in the lower tank contains a small amount of water, some of the bottom water will precipitate out of the bilge water after standing, and the water vapor will evaporate during the continuous heating process. The water vapor condenses on the antenna at the top of the tank to form water droplets, causing a strong false signal at the top. Therefore, false signals are suppressed within 0~0.25m and the suppression line is set to 120dB to avoid false signals caused by water vapor condensation and level jumps at the top. In response to this situation, after on-site analysis and research tests decided to do a good job of pre-dewatering treatment, the water content of the crude oil in the lower tank is controlled at less than 0.5%, the heating temperature of the crude oil tank is controlled so that the crude oil in the tank is lower than 65 ℃, and the instrumentation is covered with thermal insulation materials on the outside, etc. Through the above measures, the phenomenon of level jumping caused by the formation of condensation at the antenna of the radar liquid level meter is eliminated. Discover more details on flow instrumentation.

Effective Echo Management- Pulse radar technology generates echoes at certain time intervals. This feature enables radar sensors to handle echoes and distinguish echoes. A common occurrence in complex process vessels and solid material silos. This capability greatly enhances the accuracy of measurements in situations where traditional methods may struggle. The versatility and dependability of radar level measurement make it suitable for a range of applications. Here are some important areas where radar sensors excel- Process Tanks-In industries, radar level sensors are deployed to monitor levels in process tanks. Whether its chemicals, petroleum products or water treatment facilities radar sensors provide real time data to optimize process control. Storage Tanks- Large scale storage tanks require precise level monitoring to efficiently manage inventory and prevent overfilling or underfilling. Radar sensors are the trusted choice for maintaining inventory balance.

Measurement accuracy, the accuracy of ordinary radar is generally ±10mm, and the accuracy of precision radar is ±3mm. Selection according to the actual needs of production. Range, according to actual needs, choose the antenna size. Note that the actual range is reduced in complex environments. Antenna type and antenna size, the larger the antenna size, the larger the measured range and the stronger the anti-interference ability. The antenna types of radar level gauge are rod type, bell mouth type, paraboloid and so on.

With the continuous advancement of science and technology, radar water level meters have been used more and more. It has the advantages of low cost, high stability, flexibility, high reliability, low power consumption, convenient parameter setting, safe and simple maintenance, etc., and has important promotion value. Today, the editor will take you to a simple understanding of radar water level meter. Radar water level meter is a kind of measurement equipment introduced from abroad in recent years. The water level meter has mature technology, high measurement accuracy, easy installation, and is not restricted by environment and geography, so it has been widely used.

Level Measurement Considerations: Taking advantage of a specific technology’s ability to reliably address the level measurement in either of these vessels, especially the blowdown flash tank, in a plug-and-play type installation and commissioning format is an easy way to ensure optimal performance. This forgoes calibration, external hardware or inputs. Estimates of up to 49 percent of the energy can be recovered through the use of flash steam routed to heat exchangers or the deaerator to preheat boiler makeup water or support the deaeration process, respectively. In addition, better level control technology at the boiler side eliminates energy losses resulting from unnecessary blowdown to prevent carryover conditions.

So what can be done about these difficulties? Under the condition of strong dust, on the one hand, the radar with high transmitting energy can be selected, on the other hand, the measurement software with continuous measurement algorithm of wave-loss waiting can be selected. When the radar encounters strong dust, it will not misjudge the measurement result even if the radar loses wave for a short time. After entering the state of continuous measurement algorithm, if the reflection wave of real material surface can be recognized within the set waiting time, the correct measurement value of material surface can be obtained. In the past, only a few foreign radars have this function. At present, there are also domestic radars with this function, and the practical application effect is very good.

As one of the most professional magnetic level indicators manufacturers in China,Guangdong Kaidi Energy Technology Co., Ltd. provides customized solutions for a range of industrial automation process applications,such as mechanical float level indicator.We specialized in radar level gauge, fork type level switch,etc. These were implemented successfully, and KAIDI magnetic level gauge manufacturers products,such as radar level meter, magnetic level indicators, can be used in many different industries such as food & beverage, water, energy, pharmaceutical etc. See more info on https://www.kaidi86.com/. Suitable for chemical industry, petroleum industry, metallurgical industry, water conservancy and electronic industry, etc.

The radar level gauge works by electromagnetic waves. Its working principle is to measure the specific liquid level by transmitting electromagnetic waves to the measured target. After the electromagnetic waves are emitted, they are reflected by the medium. For the radar level gauge, its key function is to ensure that it can transmit magnetrol guided wave radar signals smoothly. In our industrial production site, interference often occurs, so which interference sources will affect the measurement of the radar level gauge? let’s see.

When the distance between the liquid level of the measured medium and the electromagnetic wave transmitter is less than 4m, the guided wave radar is selected. If the distance between the liquid level of the measured medium and the electromagnetic wave transmitter is greater than 4m and less than 35m, select the guided wave radar with the guided wave cable. When the distance between the liquid level of the measuring medium and the electromagnetic wave transmitter is greater than 35m, or when the liquid level of the measuring medium is high temperature, high viscosity or solid liquid level, the air-shooting radar should be selected.

Working principle: Tube in the liquid level meter has a magnetic float, float design, according to the proportion of medium float magnet steel and container liquid level at the same level, wholesale liquid level gauge in a semiconductor magnetel liquid level gauge sensor LED display scale, and orderly arranged from top to bottom, and LED module corresponding to the magnetic field magnetic sensor, the magnetic semiconductor, triggering the corresponding digital circuit, liquid level above the red LED display, The LED below the liquid level gauge is displayed in green, the red in gas phase, and the green in liquid phase. The red-green junction is the actual liquid level in the container.