Hmi touch screen wholesale manufacturer 2023: Object-oriented principle: That is, according to the identity characteristics and work nature of the operator, design a human-machine interface that is compatible and friendly. According to their work needs, it is appropriate to display prompts, guidance and help information in pop-up windows, so as to improve the level of user interaction and efficiency. HMI, whether for the field controller or for the upper monitoring and management, the two are closely interconnected, they monitor and manage the field equipment objects are the same, so many field equipment parameters are shared between them and passed to each other. The standardized design of the human-machine interface should be the future development direction, because it really reflects the easy-to-configure, simple, and practical principles of the base, fully expressing the human-centered design concept. A variety of industrial control configuration software and programming tools provide powerful support for the production of a beautiful human-machine interface, and the larger and more complex the system, the more it can reflect its superiority. Read even more information on plc controller.
System Reliability Requirements: The reliability of the general system PLC can be met. For systems with high reliability requirements, consider whether to use redundant systems or hot standby systems. PLC should be unified possible. Mainly consider the following three aspects: The model is unified, and its modules can be used as backup for each other, which is convenient for the procurement and management of spare parts. The model is unified and its function and use method are similar, which is conducive to the training of technical forces and the improvement of technical level. The model is unified, its external equipment is universal, resources can be shared, easy to network communication, and it is easy to form a multi-level distributed control system after being equipped with a computer.
Consider the typical problems in interface design: To design any interface, we must generally consider four aspects: system response time, user help mechanism, error message handling and command mode. System response time is too long is the most complained about in the interactive system, in addition to the absolute length of the response time, the user is concerned about the difference in response time of different commands, if too much disparity in the user will be difficult to accept; user help mechanism should be integrated, to avoid the superimposed system leads to the user to help a guide and have to browse a lot of irrelevant information; error and warning information must be selected user understandable The error and warning messages must be user-friendly, accurate terminology, and should also provide some suggestions for error recovery as much as possible. In addition, the display of error information, if supplemented by auditory (ringing), visual (special color) stimulation, it is more effective; command mode is best to menu and keyboard commands coexist for the user to choose.
There is no a good way that a conventional resistive screen can be implemented, becuase its only support the operation temperature from 0°C to 50°C, it is far enough to meet. But Mochuan have another series type HMI panel, wide-temperature metal shell resistive hmi panel, supporting the operation temperature from -20°C to +70°C, it is very helpful to require higher or lower operation temperature working environment, such as Canada, Russia and America …etc, when winter is coming the temperature is very low. So this type metal shell hmi panel is the best choice. So it requires a good positioning, what type of HMI screen to select. For example, used in the renovation of equipment, used in the new development of equipment, the target market is high-end or low-end, whether the customer has special requirements, or to achieve a certain expected results, these factors should be taken into account, and then to make a correct choice is very necessary.
It is good to choose a brand according to the needing of the customers or the market. But it is not for selecting a brand to decide, or more about to focus on its performance parameters, and to be used the functions achieved. Actually there is an attractive story behind the famous brand. So to choose a brand, try to achieve high practicality, to avoide waste one’s talent on a petty job. For example, Siemens, Mitsubishi, Proface, Panasonic brand…etc with a good performance, but before decision to select them, should consider, how many performance of HMI panel will be used for the project? Whether the cost paid matches the performance used on the project? Find even more info on https://www.mochuan-drives.com/.
How To Solve Communication Failure Between HMI Operator Interface And PLC? When communication fails, some customers guess that it may be a problem with the touch screen all-in-one machine or the interface. Online simulation is to bypass the touch screen, use the PLC to connect directly to the computer, use our configuration software, connect the PLC’s own communication cable to the computer, conduct online simulation and see if the project can communicate.
Multiple color of shell and panel cutout for selecting, it is more flexible to match different project to improve the overall aesthetics and practical. Suggestions and recommendations to our customers through over a decade field experience industry and industry solution through software and hardware, if you work with us. If require the special technology, special function, special size, special parameter, special color, shape or special performance of ihm, welcome contact us for ODM. Mochuan hmi panel manufacturers will be very seriously and give timely feedback.
There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.
MochuanDrives supports industrial hmi touch panel from 4.3inch to 32inch, and supports multiple serial ports with different communication parameters to meet the needs of different projects. Provide free software and online technical one-on-one worry-free after-sales technical support. Through the setting of early warning programming, can monitor in advance whether there is a failure of the equipment in the electrical room, can effectively prevent the loss of sudden damage to equipment.
Human-machine interface refers to the field of human and machine in information exchange and functional contact or mutual influence or interface said human-machine bonding surface, information exchange, functional contact or mutual influence, refers to the hard contact and soft touch of human and machine, this bonding surface includes not only the direct contact of the point line surface, but also the role of space for information transfer and control at a distance.